Technical Specifications
Product Overview
High-Performance Locomotive Ethernet Cable
This CAT5e Ethernet cable is specifically engineered for the rigorous demands of locomotive and railway applications. Featuring a robust shielded construction and LSZH jacket, it ensures reliable data transmission while maintaining excellent resistance to external electromagnetic interference. Designed for safety and durability, the cable meets strict flame resistance standards and operates effectively in extreme temperature environments.
Technical Specifications
- Operating Temperature
- -40°C to 80°C
- Test Voltage
- 1000 V
- Characteristic Impedance
- 100±15Ω @ 100MHz
- Insulation Resistance
- ≥5GΩ.km
- Min. Bending Radius
- 8D (Fixed Application)
- Reference Standard
- DIN5510-2
Construction & Materials
- Conductor
- Stranded copper wire
- Insulation
- PE or LSZH
- Shielding
- AL / Mylar screen and tinned copper wire braid
- Jacket
- LSZH
Features & Compliance
- Key Features
- Flame resistantHalogen freeLow smokeEMI resistantCAT5e compliant
- Flame Resistance Standard
- IEC60332-1